General Purpose, Multi-indicator, Switched-Mode, Power Supplies 13.8VDC 1A, 2A, 3A & 5 Ampere with battery charging

 

MANUFACTURED IN THE UK!!

 

Dycon’s D154X Series units are available as 1, 2, 3 and 5 Amp switched-mode power supplies, with three separate LED indicators that show the operational status of the unit. A green LED indicates that the Mains AC power is present, an orange LED lights when the unit is operating on standby battery power and a red LED lights if the electronic fuse has been tripped. These power supplies are protected against electrical ‘spikes’ caused by the switching of highly inductive loads (door strikes and locks). They remove the chance of inductive kickback blowing a fuse and causing a door to remain closed or open, a frequent cause of personnel delays and expensive engineer call outs. The range also features intelligent and capacitive load switching surge protection and snubbing. Optional output splitters enable a single power supply to drive a wide variety of different devices. These include 8-way splitters with individually-fused outputs, 4-way splitters with electronically-fused outputs or individually glass-fused outputs. Available is also a special unit that can power up to 4 cameras with loop-through connections for video signals, making it ideally suited for use in powering CCTV systems.

 

Specifications

 

Power Supply Type A, Ungraded, Environmental Class 2

Voltage Input 230VAC +10% -15%; 50Hz ± 15%

AC Input Current D1541-200mA: D1542-300mA; D1543-400mA; D1545-600mA

AC Input Fuse D1541-1A; D1542-2A; D1543-2A; D1545-3A

Output Voltage with AC Power Maximum 13.7VDC nominal Output Ripple < 100mV peak-to-peak at full rated output

Maximum Output Current @ Full Load D1541-1A; D1542-2A; D1543-3A; D1545-5A

Battery Charging Current and Voltage 300mA at 13.7VDC float charge voltage

Maximum Over-Voltage Cut-Out 14.4VDC ±3%

Low Battery Fault 11VDC ±3%

Low-Voltage Power Output Fault 12.3VDC ±3%

Battery Deep Discharge Voltage Limit 10VDC ±3%

Automatic Reset Time 10ms to 18s (Depending on type of duration of fault)

Operating Temperature Range -10˚C to +40˚C Humidity 95% non-condensing

 

260mm x 320mm x 90mm